    The industries such as petroleum , chemical , metallurgy, environmental protection , paper-making , municipal , biochemical medicine and water treatment.

    Working principle

    The photoionization detector provides ionization energy via a high-energy ultraviolet lamp.
    When the volatile organic compounds  (VOCs) with an ionization potential  (IP) less than the energy of the ultraviolet lamp passes through the ionization cavity, the ultraviolet light source (UV) of the PID will break the compound into detectable positive and negative ions (that is , the ionization process) . The detector measures the ionized gas charge and converts it into a current signal , which is then amplified and converted into a concentration value . Upon the detection , the ions recombine into the original gas and vapor.

    AS-525

    VOC Gas Detector

     

    ●Built-in temperature compensation circuit for accurate measurement

    ●Designed with cover-free style , infrared remote control calibration , operation

    ●Fast response speed , high measuring accuracy

    ●Multiple range options can meet requirements of customers

    ●Field level-2 sound and light alarms , relay output (with the external equipment such as external exhaust connected)

    ●Easy to install and maintain , sensor replacement on site (plug and play)

    ●Standard three-wire 4-20mA signal output or RS485 output , compatible with DCS or PLC system

     

     

     

     

     

     

     

    Technical parameters

    Principle of detection

    Photo Ionization PID

    Standard configuration

    Detector host
    Remote control
    Instructions



    Optional configuration
    Audible-visual warning light



    Accessories installation
    Mounting bracket

    Rain cover

    Gas for detection

    VoCs

    Repeatability

    ≤±2%

    Polarization time

    6 hours

    T90 reaction time

    <30s

    Self-diagnosis time

    2 times/s

    Calibration

    Every 4-8 months

    Reset

    Every 3-6 months

    User interface

    Infrared remote control

    Working temperature

    -40°℃-70℃(limit);-20°℃-50℃(typical)

    Operating pressure

    Standard atmospheric pressure±10%

    Working humidity

    0-95%RH(no condensation)

    Output signal

    4-20mA,RS485

    Connection

    Analog three-wire system

    Display

    Displayed by LCD backlight,
    gas concentration,alarm display

    Explosion-proof class

    Ex dIIC T6 Gb

    Protection grade

    IP66


Application industry

Environmental Protection Industry

Environmental Protection Industry

We have developed and launched a series of water quality analyzers, flow meters, liquid level gauges, and gas detectors for applications in municipal drinking water, municipal sewage, industrial wastewater, spa pool disinfection, space disinfection, chemical plant gas leak emission detection, and other fields.

Energy

Energy

We have developed and launched a series of water quality analyzers, flow meters, liquid level gauges, and gas detectors for applications in municipal drinking water, municipal sewage, industrial wastewater, spa pool disinfection, space disinfection, chemical plant gas leak emission detection, and other fields.

Food Manufacture & Processing

Food Manufacture & Processing

We have developed and launched a series of water quality analyzers, flow meters, liquid level gauges, and gas detectors for applications in municipal drinking water, municipal sewage, industrial wastewater, spa pool disinfection, space disinfection, chemical plant gas leak emission detection, and other fields.

Chemical Engineering

Chemical Engineering

We have developed and launched a series of water quality analyzers, flow meters, liquid level gauges, and gas detectors for applications in municipal drinking water, municipal sewage, industrial wastewater, spa pool disinfection, space disinfection, chemical plant gas leak emission detection, and other fields.


Download

Document

size

Download

AS-525 VOC Gas Detector

24.5MB

Bebur Gas detector

116.8MB

Products

Professional water quality and gas detection solutions

Online Laser Particle Counter-BT8200

Online Laser Particle Counter-BT8200

BT8200 Particle Counter is a particle counting instrument that applies laser principle to monitor the size,quantity and change of particulate matter in water continuously for 24h online.The instrument has reliablee performance and easy to use.Multiple particle size detection channels could meet the diverse needs of users.

More details

Steaming Current Detector-SCM530

Steaming Current Detector-SCM530

BT6308-SMC530 Streamer range of Streaming Current Monitors you get a world's first. BT6308-Streamer streaming current monitor is the first in the world to be designed in modular form so that it can be integrated with other sensors such as pH and UV254 to provide all the tools needed for a coagulation monitoring or a coagulation control instrumentation package.

More details

SET-PB3000-L Pump aspirated gas detector

SET-PB3000-L Pump aspirated gas detector

More details

Residual Chlorine Analyser

Residual Chlorine Analyser

Residual Chlorine Analyser The BT6308-CL range of Residual Chlorine Analysers, Residual Chlorine Controllers and Residual Chlorine Monitors utilise the very latest and best chlorine sensors available in the world today. They are membrane devices which are insensitive to changing pH, use no reagents, are extremely stable, and have reduced maintenance and reduced whole life costs.

More details

DPD Online Residual Chlorine/ Total Chlorine Water analyzer

DPD Online Residual Chlorine/ Total Chlorine Water analyzer

The Bebur BC350Online Residual Chlorine/ Total Chlorine Water  analyzer is acompact, well-structured and easy to operate water  analysis instrument. The analyzer measures residual chlorine and total chloring in water using the DPD colorimetric method: Reagents are injected into the water sample by a reagent pump to complete the reaction,and the DPD Colorimetric method is then used to accurately determin the sample concentration. Users can select different reagents to achieve targeted measurement of residual chlorine or total chlorine. In addition, the instrument is equipped with a large-capacity data storage module,which can store test data for more than 10 years, helping users analyze long-term water quality variation trends.

More details

BT8500 Praticle Counter

BT8500 Praticle Counter

BT8500 Particle Sense particle counter is a particle counting instrument that uses the photo resist principle to monitor the size,quantity and change of particles in water continuously for 24 hours online.The instrument has reliable performance and is easy to use.It has multiple particle size detection channels to meet the diverse needs of users.

More details

price inquiry

Submit