Online Laser Particle Counter Portable particle counter BT-6308 Controller Online Streaming Current Detector Lab sense-Laboratory Particle Charge Analyzer BT-9000S Coagulation Intelligent Dosing Control System BT-9000C Chlorination and disinfection control system BT-9000L Coagulation Intelligent Dosing Control System Ozone Analyzer Residual Chlorine/Total Chlorine Analyzer Chlorine Dioxide Analyzer Hydrogen Peroxide Analyzer Peracetic Acid Analyzer Free Bromine/Total Bromine Analyzer Online pH Analyzer Online ORP Analyzer Conductiviy Analyzer Turbidity Analyzer Turbidity/Suspended Solids/Sludge Concentration Analyzer BT-7000 Online Multi-Parameter Analyzer Dissolved Oxygen Analyzer Hardness Tester NH3-N Water Quality Analyzer UV Sense Series Spectrum Analyzer Fluoridelon Online Analyzer Auto Cleaning Device Ultrasonic Level Gauge Electromagnetic Flowmeter Integrated Electromagnetic Flowmeter Gas Detector
-
-
- All
- Product Management
- News
- Introduction
- Corporate Outlets
- FAQ
- Corporate Video
- Corporate Brochure
Daily maintenance of water quality analysis instruments
Daily maintenance of water quality analysis instruments
① Residual chlorine analyzer
The Bebur residual chlorine analyzer does not incur any consumables costs in the first year and does not require zero calibration. After one year of normal use, the sensor membrane cap needs to be replaced once a year or longer (depending on the water quality). Only one bottle of electrolyte needs to be purchased each year. If the water quality is not very good, it is recommended to replace the sensor membrane cap halfway.
② Turbidity Analyzer
The Bebur turbidity analyzer uses IR LED optical sensor and does not require consumables. If the instrument is calibrated according to water samples, there is no need to purchase standard solution. If the instrument is calibrated with standard solution, you can purchase turbidity standard solution yourself or from our company. The sensor and flow cell are easy to disassemble and clean.
③ PH analyzer
If the instrument needs to be calibrated according to water samples, there is no need to purchase standard solution; if standard solution is needed, you can purchase PH standard solution yourself or from our company. Usually, you only need to use tap water to clean the electrode and circulation pool.
④ Conductivity Analyzer
Conductivity analyzers are divided into graphite sensors, ring electrode sensors and stainless steel sensors, which are selected according to different application processes and temperatures. Usually, you only need to clean the electrodes and circulation pool with tap water as needed.
⑤ Dissolved oxygen analyzer
According to the fluorescence detection principle, you only need to clean the electrodes and circulation pool with tap water as needed.
⑥ ORP Analyzer
If you need to calibrate based on water samples, you do not need to buy standard solution; if you need to use standard solution to calibrate the instrument, you can buy ORP standard solution yourself or from our company. Usually, you only need to clean the electrode and circulation pool with tap water as needed.
Latest news
Catalogue
Application
About Us
Contact Us
Bebur Beijing China(Marketing &Sales)
sales@bebur-tech.com
Bebur Sichuan China
( Factory&After sales Service)
technology@bebur-tech.com
Bebur UK
info@bebur-tech.com
Tel:
E-mail:
Whatsapp:
skype:
导航下拉添加类名.active
在线客服添加返回顶部
右侧在线客服样式 1,2,3 1
图片alt标题设置: Bebur
表单验证提示文本: Content cannot be empty!
循环体没有内容时: Sorry,no matching items were found.
CSS / JS 文件放置地