Welcome to Bebur, The world-leading provider of water quality and gas detection solutions!

Tel

Welcome to call us

+44(0)7962654688

+86 18518487185

Language

Language

中文

EN

All
  • All
  • Product Management
  • News
  • Introduction
  • Corporate Outlets
  • FAQ
  • Corporate Video
  • Corporate Brochure
EN CN RU
back all
Peracetic Acid Analyzer
+
  • Peracetic Acid Analyzer

Peracetic Acid Analyzer

For Bebur peracetic acid analyzer in water, a membrane sensor is used, and reagents and buffers are not used. It has the features such as stable measurement and reliable performance,which can reduce the maintenance workload and reduce the cost of use for customers.

sales@bebur-tech.com

+86-18518487185

  • Product details
  • Overview:
    For Bebur peracetic acid analyzer in water, a membrane sensor is used, and reagents and buffers are not used.
    It has the features such as stable measurement and reliable performance,which can reduce the maintenance workload and reduce the cost of use for customers.

    Typical Applications:
    ·For online monitoring of peracetic acid concentration in drinking water,sewage industrial process water and purified water disinfection and sterilization process, such as:
    ·Dosing control of bottle washing machine
    ·CIP factory application
    ·Food cleaning water and bleaching system
    ·Fields such as pharmaceutical factories or pharmaceutical intermediates

    Performance Features:
    ·Membrane-type amperometry principle sensor
    · Stable performance and accurate measurement result
    ·Chemical reagent is not required
    ·Unaffected by detergent in water
    ·Zero-scale cal ibration is not required
    ·Long service life
    ·For drinking water,process water and brine

    Working Principle:
    The peracetic acid sensor is a membrane dual-electrode system, which can automatically adjust the potential to eliminate zero drif. Such design allows carrying out water quality test without using an additional reagent or buffer, reducing the cost of use for users. When calibrated, only high point calibration is required (Zero-point adjustment is not necessary).
    The peracetic acid analyzer in water can perform automatic dosing process control, which can control the dose of CH,CO,H (Peracetic Acid) by automatically adjusting the flow rate, pump speed or valve position to maintain the concentration of peracetic acid at a preset value. Automatic dosing could reduce the use cost of reagent and improve the level of process control.

    Instructions for Ordering
    Nhen purchasing, please inform the field or industry of use and the characteristics of the measuring medium in order to provide appropriate technical service guidance.
    Standard supplies of peracetic acid analyzer in water are as follows.

    Item

    Controller

    Sensor

    Membrane cap

    Electrolyte

    Flow cell

    Peracetic-Acid Analyzer

    BT6308

    BPES7

    M7.1N,M7.1L

    EPS7/W, EPS7L/W

    FC01

    Peracetic-Acid Analyzer

    BT6308

    BP9.2

    M9.1N/G-H

    EPS9H/W, EPS9L/ W

    FC01

    Peracetic-Acid Analyzer

    BT6308

    BP10

    M10.1N+G,M10. 1G+G

    EPS9H/W,EPS9L/ W

    FC01

     

    Sensor Parameters: 

    Type

    Membrane-covered, amperometric 2-electrode system

    Membrane-covered, amperometric 2-electrode system

    Membrane-covered, amperometric 2-electrode system

    Range

    0.5-200,5-500,5-1000,5-2000, 50-5000,50-10000(ppm)

    0.5-200,5-2000, 50-20000(ppm)

    0-20,0-200,0-2000,50-5000,50-20000, 50-50000(ppm)

    Resolution

    0.1 ppm,1ppm,10ppm

    0.1 ppm,1ppm,10ppm

    0.1 ppm,1ppm,10ppm

    pH Range

    pH1-6

    pH1-6

    pH1-6

    Temperature Range

    0-45℃ (not any ice crystal in test water)

    0-60℃ (not any ice crystal in test water)

    0-45℃ (not any ice crystal in test water)

    Temperature Compensation

    Automated by an integrated temperature sensor

    Integrated automatic temperature compensation

    Integrated automatic temperature compensation

    Pressure Range

    0.5bar,no pressure shock or vibration

    0.5bar, no pressure shock or vibration

    0.5bar, no pressure shock or vibration

    Polarization Time of Initial Utilization

    Approx.3h

    30-180min

    30-180min

    Response Time

    T90 approx. 3min

    T90,approx. 3.5min at 10℃; Approx. 45s at 50℃

    T90,approx.1.5-3.5min (depending on type and temperature)

    Requirements for Flow Rate

    Approx.0.5 L/min

    Approx. 0.5 L/min

    Approx.0.5 L/min

    Materials

    PVC-U,stainless steel 1.4571

    PEEK, stainless steel 1.4571

    PVC-U, stainless steel 1.4571

    Calibration

    Recommended calibration every 1-3 months

    Recommended calibration every 1-3 months

    Recommended calibration every 1-3 months

    Interference

    Chlorine dioxide, hydrogen peroxide,ozone

    Chlorine dioxide,hydrogen peroxide,ozóne

    Chlorine dioxide, hydrogen peroxide,ozone


    Mounting Options 


Application industry


Cases


Download

Document

size

Download

BT6308 PAA

2.8MB

Products

Professional water quality and gas detection solutions

ozone gas detector

ozone gas detector

More details

UV sense for COD chemical oxygen demand analyzer

UV sense for COD chemical oxygen demand analyzer

Bebur UVSense series UV-visible spectrum analyzer employs UV-visible spectroscopy to measure the composition of organic matter in water, including TOC, BOD, COD, NO3-N and DOC. The sensor with a turbidity compensation function enhances measurement accuracy in actual conditions, making it suitable for online monitoring of waterworks, water treatment, domestic wastewater, industrial wastewater and natural water body.

More details

UV sense  BOD analyzer Biochemical Oxygen Demand analyzer

UV sense BOD analyzer Biochemical Oxygen Demand analyzer

Bebur UVSense series UV-visible spectrum analyzer employs UV-visible spectroscopy to measure the composition of organic matter in water, including TOC, BOD, COD, NO3-N and DOC. The sensor with a turbidity compensation function enhances measurement accuracy in actual conditions, making it suitable for online monitoring of waterworks, water treatment, domestic wastewater, industrial wastewater and natural water body.

More details

UV sense TOC analyzer

UV sense TOC analyzer

Bebur UVSense series UV-visible spectrum analyzer employs UV-visible spectroscopy to measure the composition of organic matter in water, including TOC, BOD, COD, NO3-N and DOC. The sensor with a turbidity compensation function enhances measurement accuracy in actual conditions, making it suitable for online monitoring of waterworks, water treatment, domestic wastewater, industrial wastewater and natural water body.

More details

Sludge Concentration analyzer

Sludge Concentration analyzer

Bebur BT-6308 series turbidity/suspended solids/sludge concentration analyzer applies the principle of scattered light to measure the turbidity and suspended solids in water. The sensor is small in size, easy to install and maintain, not easily disturbed by ambient light, and has excellent repeatability and stability. The sensor is equipped with an automatic cleaning brush, which can effectively eliminate the impact of bubbles and stains on the measuring results, enabling the sensor to maintain a longer maintenance period and maintain good stability during operating.

More details

Turibidity analyzer (0.1-4000NTU)

Turibidity analyzer (0.1-4000NTU)

Bebur BT-6308 series turbidity/suspended solids/sludge concentration analyzer applies the principle of scattered light to measure the turbidity and suspended solids in water. The sensor is small in size, easy to install and maintain, not easily disturbed by ambient light, and has excellent repeatability and stability. The sensor is equipped with an automatic cleaning brush, which can effectively eliminate the impact of bubbles and stains on the measuring results, enabling the sensor to maintain a longer maintenance period and maintain good stability during operating.

More details

price inquiry

Submit