Welcome to Bebur, The world-leading provider of water quality and gas detection solutions!

Tel

Welcome to call us

+44(0)7962654688

+86 18518487185

Language

Language

中文

EN

All
  • All
  • Product Management
  • News
  • Introduction
  • Corporate Outlets
  • FAQ
  • Corporate Video
  • Corporate Brochure
EN CN RU
back all
  • Product details
  •  BT3500-OZ series ozone analyzer uses the ultraviolet dualpath absorption method for real-time detection of ozone generator outlet concentration or exhaust gas ozone concentration. It can continuously monitor the ozone concentration in the outlet pipeline of the ozone generator. It is mainly used for continuous detection of ozone gas in various industrial environments, and can also be used to detect ozonegas in operating pipelines, containers, and other environments. It is widely used in pharmaceutical, chemical, municipal, and sewage treatment industries for measuring ozone generator outlet concentration and ozone generator output.
     

    The BT3500-0Z series ozone analyzer, based on Beer-Lambert's law, calculates the current ozone concentration by measuring the change in light signal intensity before and after ozone absorption of ultraviolet light. The equipment utilizes
    an advanced dual-path ultraviolet light source system with an integrated intelligent lamp management system, ensuring the ultraviolet lamps quickly reach measurement mode upon startup. Employing separate photocell technology, the equipment
    features leak-free operation, high pressure resistance, resistance to high-flow-rate sampling gas impact, easy cleaning, convenient maintenance, simple operation, and low operating costs.

    The BT3500-OZ features an automatic zero-point purging every 72 hours to ensure zero-point stability and prevent zero point drift from affecting the accuracy of the detected concentration. During zeroing, the gas flow rate, pressure, and
    velocity remain constant to prevent airflow impact from affecting the zeroing process, ensuring that the equipment can operate continuously 24 hours a day.

    Features
    Measurement Principle: Dual-path ultraviolet absorption method
    Test Method: Dual-path ultraviolet absorption method, high measurement accuracy, temperature and pressure coefficient compensation
    Light Source System: Ultraviolet LED (wavelength 254nm)
    Photovoltaic Cell System: Separate photovoltaic cell technology, leak-free, high pressure resistant, and resistant to high-flow-rate sampling gas impact
    Intelligent Compensation: Built-in automatic light source compensation function
    Automatic Zeroing: The device automatically zeroes every 72 hours to ensure zero-point stability and guarantee the accuracy of the detected concentration.
    Output Functions: 4-20mA current signal, RS485 communication (optional)
    Data Display: 5.0-inch touchscreen, user-friendly interface
    Ozone generator manufacturers serve industries such as municipal water supply, industrial wastewater treatment, fine
     
    Application areas
    Chemicals, food and drinking water, space disinfection, swimming pool disinfection, and fragrance synthesis.
     
    Technical parameters
    Detected GasOZONE
    Measurement Range0-50mg/NL;0-200mg/NL;0-300mg/NL;0-400ng/NL
    Detection PrincipleUltraviolet Absorption
    Method
    Detection ModeOnline
    Detection Accuracy≤±2NFSResolution0.1mg/NL;0.01mg/NL
    Zero Drift<±0.1%FS(MAX:±0.2mg/NL)Response Time≤5S
    Recovery Time≤20SLinear Error≤±1%
    Display5.0inch Touch ScreenOutput Mode4-20mA,Linear
    Housing MaterialGalvanized SheetPower SupplyAC 110-220V
    Concentration UnitSwitchable:mg/NL,  g/Nm³,%(wt),  ppm
    1mg/NL=1g/Nm³=467ppm
    Weight6.5kgInstrument Dimensions270*340*130mm(LWH)
    Mounting Dimensions175*300mmTemperature Range‘-20℃~+70℃(High-
    temperature  adaptable)
    Humidity Range10-95%RH
    (No  Condensation)
    Pressure Range<0.1MPa(High-pressure adaptable)
    Power Consumption<12WSampling Port Pipe Diameterφ6(6mm*4mm)


     

Prev

Next

Prev

Next


Application industry


Cases


Download

Document

size

Download

BT3500-OZ

698.1KB

Products

Professional water quality and gas detection solutions

ozone gas detector

ozone gas detector

More details

UV sense for COD chemical oxygen demand analyzer

UV sense for COD chemical oxygen demand analyzer

Bebur UVSense series UV-visible spectrum analyzer employs UV-visible spectroscopy to measure the composition of organic matter in water, including TOC, BOD, COD, NO3-N and DOC. The sensor with a turbidity compensation function enhances measurement accuracy in actual conditions, making it suitable for online monitoring of waterworks, water treatment, domestic wastewater, industrial wastewater and natural water body.

More details

UV sense  BOD analyzer Biochemical Oxygen Demand analyzer

UV sense BOD analyzer Biochemical Oxygen Demand analyzer

Bebur UVSense series UV-visible spectrum analyzer employs UV-visible spectroscopy to measure the composition of organic matter in water, including TOC, BOD, COD, NO3-N and DOC. The sensor with a turbidity compensation function enhances measurement accuracy in actual conditions, making it suitable for online monitoring of waterworks, water treatment, domestic wastewater, industrial wastewater and natural water body.

More details

UV sense TOC analyzer

UV sense TOC analyzer

Bebur UVSense series UV-visible spectrum analyzer employs UV-visible spectroscopy to measure the composition of organic matter in water, including TOC, BOD, COD, NO3-N and DOC. The sensor with a turbidity compensation function enhances measurement accuracy in actual conditions, making it suitable for online monitoring of waterworks, water treatment, domestic wastewater, industrial wastewater and natural water body.

More details

Sludge Concentration analyzer

Sludge Concentration analyzer

Bebur BT-6308 series turbidity/suspended solids/sludge concentration analyzer applies the principle of scattered light to measure the turbidity and suspended solids in water. The sensor is small in size, easy to install and maintain, not easily disturbed by ambient light, and has excellent repeatability and stability. The sensor is equipped with an automatic cleaning brush, which can effectively eliminate the impact of bubbles and stains on the measuring results, enabling the sensor to maintain a longer maintenance period and maintain good stability during operating.

More details

Turibidity analyzer (0.1-4000NTU)

Turibidity analyzer (0.1-4000NTU)

Bebur BT-6308 series turbidity/suspended solids/sludge concentration analyzer applies the principle of scattered light to measure the turbidity and suspended solids in water. The sensor is small in size, easy to install and maintain, not easily disturbed by ambient light, and has excellent repeatability and stability. The sensor is equipped with an automatic cleaning brush, which can effectively eliminate the impact of bubbles and stains on the measuring results, enabling the sensor to maintain a longer maintenance period and maintain good stability during operating.

More details

price inquiry

Submit