Online Laser Particle Counter Portable particle counter BT-6308 Controller Online Streaming Current Detector Lab sense-Laboratory Particle Charge Analyzer BT-9000S Coagulation Intelligent Dosing Control System BT-9000C Chlorination and disinfection control system BT-9000L Coagulation Intelligent Dosing Control System Ozone Analyzer Residual Chlorine/Total Chlorine Analyzer Chlorine Dioxide Analyzer Hydrogen Peroxide Analyzer Peracetic Acid Analyzer Free Bromine/Total Bromine Analyzer Online pH Analyzer Online ORP Analyzer Conductiviy Analyzer Turbidity Analyzer Turbidity/Suspended Solids/Sludge Concentration Analyzer BT-7000 Online Multi-Parameter Analyzer Dissolved Oxygen Analyzer Hardness Tester NH3-N Water Quality Analyzer UV Sense Series Spectrum Analyzer Fluoridelon Online Analyzer Auto Cleaning Device Ultrasonic Level Gauge Electromagnetic Flowmeter Integrated Electromagnetic Flowmeter Gas Detector
-
-
- All
- Product Management
- News
- Introduction
- Corporate Outlets
- FAQ
- Corporate Video
- Corporate Brochure
Application scenario of peracetic acid analyzer
The peracetic acid analyzer is mainly used to detect and monitor the concentration of peracetic acid (a highly efficient disinfectant) to ensure its effectiveness and safety in disinfection, sterilization and other scenarios.
Peracetic acid analyzer application scenario
Medical industry
Environmental disinfection monitoring of drug production: in the process of drug production, it is necessary to strictly disinfect the production workshops and clean rooms, and peracetic acid is often used for space and surface disinfection. The peracetic acid analyzer can monitor the concentration of peracetic acid in the process of disinfection in real time to ensure the disinfection effect, ensure that the drug production environment meets the health standards, and prevent the microbial contamination of drugs.
Disinfection detection of medical devices: for the disinfection of surgical instruments, syringes, infusion sets and other medical devices, peracetic acid is also one of the commonly used disinfectants. Peracetic acid analyzer can accurately measure the concentration of peroxyacetic acid solution, help the staff to master the effectiveness of disinfection solution, ensure the disinfection quality of medical devices, and avoid cross-infection.
The food and beverage industry
Disinfection of food processing equipment: in the process of food processing, various kinds of pipelines, conveyor belts, containers and other equipment need to be disinfected regularly. Peroxyacetic acid can effectively kill bacteria, viruses and fungi and other microorganisms on the surface of the equipment. Peracetic acid analyzer can be used to monitor the concentration change of peracetic acid during the disinfection of equipment to ensure that the equipment is thoroughly disinfected and prevent food pollution caused by microbial breeding. Food raw materials and packaging disinfection: in fruits, vegetables and other food raw materials cleaning and disinfection, and the disinfection of food packaging materials, peracetic acid analyzer can be used on the concentration of peracetic acid accurate detection, make the disinfection process can achieve sterilization purpose, and not for peracetic acid residue impact on food quality and safety.
Disinfection of beverage production: In beverage production, peroxyacetic acid may be used either in the disinfection of bottle body and bottle cap, or in the disinfection of production pipelines and filling equipment. Through the monitoring and control of the peroxyacetic acid concentration in the disinfection process by the peroxyacetic acid analyzer, the microbial index of the beverage products can be guaranteed to be qualified and the shelf life of the products can be extended.
Lab study
Chemical analysis experiment: in the chemical laboratory, peracetic acid is often used as a strong oxidant for various chemical reactions and analysis experiments. Peracetic acid analyzer can help the experimenter to accurately measure the concentration of peracetic acid, provide accurate data support for the experiment, and ensure the accuracy and reliability of the experimental results.
Microbial experiment: In microbial culture and research, the experimental environment and equipment need to be strictly disinfected. The peracetic acid analyzer can be used to monitor the concentration of peracetic acid in the disinfection process to ensure the disinfection effect and create sterile environmental conditions for microbial experiments.
Water treatment
Sewage treatment: peroxyacetic acid can be used in the disinfection and oxidation process of sewage treatment, can effectively remove the organic matter, ammonia nitrogen and other pollutants in sewage, but also can kill the pathogens in sewage. The peracetic acid analyzer can monitor the content of peracetic acid in sewage in real time, help the staff to adjust the amount of peracetic acid according to the water quality, improve the effect of sewage treatment, and ensure that the effluent quality reaches the standard.
BeburBT6308-Pera Peracetic acid analyzer
BeburBT6308-Perera peracetic acid analyzer uses membrane sensor, no reagents and buffers, measuring stable, reliable performance, can reduce the maintenance and reduce the cost of users.
Operational principle
Electrochemical (membrane-type amperometric method) principle. The sensor of the BeburBT6308-Pera is a coated amperometric double electrode system. The working electrode is covered by a diaphragm and located with the reference electrode in the electrolyte area, which contains a special electrolyte separated from the water sample. During testing, peracetic acid diffused from the water sample, through the diaphragm, with the help of the electrolyte, generated an electrical signal on the working electrode, which is proportional to the peracetic acid concentration and amplified through the circuit in the sensor. Due to the integration of temperature compensation, the measured signal is independent of the water sample temperature.
Technical parameter
Range: 0.5-200, 5-2000, 50-20000ppm resolution: 0.1, 1,10ppmpH range: pH1-8 Temperature range: 0-60℃ (no ice crystals in measured water) Temperature compensation: integrated automatic temperature compensation pressure range: 0.5bar, No pressure impact or vibration first use polarization time: 30-180min flow rate requirement: about 0.5 L/min Material: PEEK, Stainless steel 1.4571 Installation method: The core value of installing the peracetic acid analyzer in the circulation tank is to accurately detect and monitor the concentration of peracetic acid, Ensure its effectiveness and safety in disinfection and sterilization scenarios, Its application scenarios mainly include medical treatment, food and beverage, laboratory research and water treatment and other industries. Bebur is committed to providing reliable peracetic acid detection solutions for users to solve the problem of peracetic acid detection.
Latest news
Catalogue
Application
About Us
Contact Us
Bebur Beijing China(Marketing &Sales)
sales@bebur-tech.com
Bebur Sichuan China
( Factory&After sales Service)
technology@bebur-tech.com
Bebur UK
info@bebur-tech.com
Tel:
E-mail:
Whatsapp:
skype:
导航下拉添加类名.active
在线客服添加返回顶部
右侧在线客服样式 1,2,3 1
图片alt标题设置: Bebur
表单验证提示文本: Content cannot be empty!
循环体没有内容时: Sorry,no matching items were found.
CSS / JS 文件放置地